微电极拉制仪
仪器介绍
P-2000微电极拉制仪以CO2激光为热源,可以拉制微量移液管、光纤探针和纳米喷雾尖端。P-2000/G可对外径为1.2mm的玻璃进行均匀加热。P-2000/G也可加工较大直径的玻璃管(最多1.5mm石英和1.8mm传统玻璃),但加工直径小于等于1.2mm的玻璃管时性能最好。
参数
Compatibility | Capable of pulling quartz, borosilicate and aluminosilicate glass. |
Programs | Fully programmable - including heating filament characteristics. |
Lasers | CO2 laser-based heat source. The laser has no melting point limit as with conventional metal filaments; and therefore, cannot be burned out. |
Tip diameters | Pulls electrodes with tip diameters smaller than 0.03µm. |
Electrodes diameters | It is suitable for electrodes with diameters greater than 0.6 mm. |
Quality control | EM detects electrode tip changes of less than 0.1 μm. |
Temperature of the laser heating zone | The temperature of the laser heating zone should be greater than 2200 °C, and the pulling temperature is not limited. |